Get the connector wrong on a CCTV run and the fault won't show up as a dead camera — it'll show up months later as random dropouts your DVR logs blame on…

On this page
- Are All RJ45 Connectors the Same?
- Shielded vs unshielded
- Solid vs stranded core compatibility
- RJ45 Connectors for Cat6 Cable: What Actually Fits?
- What to fit on a standard unshielded Cat6 run
- Crimp vs Pass-Through RJ45: Which Terminates Faster on Site?
- Standard crimp: precise, but unforgiving
- Pass-through: see it, then trim it
- How Do You Terminate an RJ45 Connector for a CCTV Camera Run?
- Recommended kit
Get the connector wrong on a CCTV run and the fault won't show up as a dead camera — it'll show up months later as random dropouts your DVR logs blame on "network instability." Camera not powering up over PoE and cable calculator, footage stuttering at random, a link that fails only when it rains: a common cause can be sitting inside the plug, not the cable.
This guide breaks down which RJ45 connector actually suits your run, and how to terminate it so it doesn't come back to haunt you.
Are All RJ45 Connectors the Same?
No — RJ45 connectors differ by shielding, contact style and body design, and picking the wrong one for your cable and site can leave you with an unreliable termination rather than a tidy one.
Shielded vs unshielded
Shielded plugs are the right call when the cable runs near motors, contactors or mains cabling. They bond the cable's screen or drain wire to the connector body, and that shield is typically carried to earth via matching shielded jacks, patch panels and equipment as part of the site's overall grounding plan — not necessarily earthed at both the patch panel and the camera end, which can cause problems of its own depending on the rest of the channel.
Our RJ45 Cat6 Pass-Through Shielded Connector is built this way, an 8P8C shielded plug for Cat6 cable. Unshielded plugs, such as our CAT6 RJ45 Plugs, are lighter and quicker to terminate, and are fine on clean data-only runs away from interference.
Solid vs stranded core compatibility
Get this wrong and you'll get an unreliable, high-resistance contact rather than an outright fail. A connector's contact blades are cut to pierce one conductor type — solid core, typical for fixed CCTV and structured cabling runs, or stranded core, used in flexible patch leads.
Using the wrong plug on the wrong core can pass a quick continuity check but fail intermittently once the cable flexes or the run heats up — a common enough cause of nuisance dropouts, alongside water ingress, poor strain relief and bad crimps.
RJ45 Connectors for Cat6 Cable: What Actually Fits?
A Cat6 cable needs a Cat6-rated 8P8C body, not a Cat5e plug squeezed onto it. The thicker conductors and larger cable outer diameter common on Cat6 need the wider internal channel a Cat6 plug is moulded for. Cat5e and Cat6 connectors both use the same 8P8C footprint that people generally mean when they say "RJ45", which is why the two are often mixed up on site. The internal geometry differs, though, and a Cat5e-sized plug can pinch a Cat6 conductor or leave a strand proud of the contact.
Why the body size matters, not just the label
Cat6 conductors are commonly 23AWG against 24AWG on Cat5e, though actual gauge varies by manufacturer, and the cable jacket itself often runs thicker to keep the twisted pairs separated for better crosstalk performance. Squeeze that into a Cat5e-profile plug and one or more of the eight conductors can sit slightly off the gold contact. That can show up later as an intermittent link rather than a dead one — often a harder fault to trace on an installed CCTV run.
What to fit on a standard unshielded Cat6 run
For ordinary Cat6 UTP terminations, fit a plug rated for Cat6 rather than a Cat5e or generic 8P8C plug. The CAT6 8P8C Modular Plug uses 50µ gold-plated contacts and a three-piece sled/liner/main-body design.
Each of the eight conductors sits in its own channel before the crimp, which helps stop a conductor slipping out of alignment mid-crimp. A plug that crimps cleanly but tests intermittently can often be traced back to exactly that kind of misalignment.
Crimp vs Pass-Through RJ45: Which Terminates Faster on Site?
Pass-through RJ45 connectors terminate faster on a typical CCTV first-fix because all eight conductors feed straight through the front of the plug before trimming, rather than being cut to length and threaded individually into eight separate channels. For a camera run where you're already juggling a ladder, a fixing bracket and a length of Cat6, cutting that fiddling step out matters more than the tool cost difference.
Standard crimp: precise, but unforgiving
Standard crimp plugs are more fiddly to get right because every conductor has to be trimmed to an even length before it goes anywhere near the plug body. With a plug such as the CAT6 8P8C Modular Plug, you strip the jacket, untwist the pairs, trim all eight conductors to an even length by colour code, then push them into the plug body before crimping.
Get that trim length even slightly wrong and one conductor stops short of its contact blade. That can leave an intermittent link that only drops out under load, vibration or thermal movement, rather than failing outright on test.
Pass-through: see it, then trim it
Pass-through plugs let you check the wiring before you commit, because the conductors run the full length of the plug and stay visible until the crimp. A plug like the RJ45 Cat6 Pass-Through Shielded Connector 8P8C lets you confirm colour-code alignment through the clear body before crimping.
A pass-through crimp tool then trims the excess flush at the same time it seats the contacts, removing the separate trim-to-length step entirely.
How Do You Terminate an RJ45 Connector for a CCTV Camera Run?
Strip the jacket back roughly 12–15mm, order the eight conductors to T568B, trim them square, seat them fully in the plug, then crimp once with a correctly rated tool. Rushing any of those steps is a common cause of intermittent dropout weeks after the install passes its first test, alongside things like poor strain relief or water ingress at an external gland.
Step 1 – Strip without nicking. Set a cable stripper to the correct blade depth rather than running a knife freehand. A nicked conductor can still pass a continuity test on day one and fail intermittently once the run flexes or heats up.
Step 2 – Order the pairs to T568B. T568B is commonly used on UK CCTV and data installs; T568A turns up too, so the priority is consistency across a site rather than mixing schemes on the same patch panel. Untwist each pair only as far as needed, flatten them side by side, and keep the sequence tight before trimming.
Step 3 – Trim square. For a standard crimp plug such as the CAT6 RJ45 Plugs, trim the conductors roughly level with the plug body so each wire reaches its contact blade when seated. For a pass-through design like the RJ45 Cat6 Pass-Through Shielded Connector, don't pre-trim at all. Feed the conductors straight through the front of the plug and let the pass-through crimping tool trim the excess flush on the crimp stroke.
Step 4 – Seat the plug in the matching die. Confirm the crimp tool die matches your plug's contact layout.
Recommended kit
For the setup above, this is the kit we'd fit from our own range:
- CAT6 RJ45 Plugs | CCTV Line UK — Gold-plated RJ45 Cat6 plugs with snagless boot, ideal for CCTV and network setups. High-speed Ethernet connections for UK installers and trade.